p0489[0...2] Activate measuring probe 2
Changeable: T, U Data type: Integer16 P group: Encoder
Min: 0 Max: 211 Def: 0
Description: Setting to activate/de-activate measuring probe 2.
The inversion of probe 2 is set in p0490.1.
Value: 0: No measuring probe
211: DI 1 (X130 / 1.5)
Index: [0] = Encoder 1
[1] = Reserved
[2] = Reserved
Dependency: See also: p0488, p0490
CAUTION
In order to prevent incorrect measurement values, these parameters may not be written during an active
measurement.
Note
DI: Digital Input
Refer to the encoder interface for PROFIdrive.
p0490 Invert measuring probe
Changeable: T, U Data type: Unsigned32 P group: Encoder
Min: - Max: - Def: 0000 bin
Description: Setting to invert digital input 0 or 1 (probe 1, 2).
Bit field: Bit Signal name 1 signal 0 signal FP
00 DI 0 (X130 / 1.2) Inverted Not inverted -
01 DI 1 (X130 / 1.5) Inverted Not inverted -
Dependency: See also: p0488, p0489
Note
DI: Digital Input
The inversion has no effect on the status display of the digital inputs (r0722).
r0550[0] Brake status
Data type: Integer16 P group: Motor
Description: Displays the status of the brake.
The value of r0550 is read when the drive powers up.
Value: 0: No data
1: Holding brake
Dependency: See also: p1215, p1216, r1216, p1217, r1217
p0613[0] Motor temperature model ambient temperature
Changeable: C2(3), T, U Data type: FloatingPoint32 P group: Motor
Min: -40 [°C] Max: 100 [°C] Def: 20 [°C]
Description: Sets the motor ambient temperature.
Based on this value, the motor temperature model calculates the thermal motor utilization (r0034).
Dependency: See also: r0034
See also: F07011, A07012
r0722 Digital inputs status
Data type: Unsigned32 P group: Commands
Parameters
12.2 List of parameters
SINAMICS S210 servo drive system
Operating Instructions, 12/2017, A5E41702836B AA 237