5.3.2 Dimension drawings and drilling dimensions
Leave a minimum 100 mm clearance to other devices at the top and bottom. A lateral clearance
between multiple SINAMICS S210 converters is not mandatory. Observe a lateral clearance
of at least 10 mm to other devices.
'HSWK


:LGWK
+HLJKW












Figure 5-3 Dimension drawing and drilling dimensions
Frame size Width Height Depth Weight
FSA 45 mm 170 mm 170 mm 1.1 kg
FSB 55 mm 170 mm 170 mm 1.2 kg
FSC 70 mm 170 mm 195 mm 1.9 kg
!!
!!
!!
ุ
Figure 5-4 Distances to cabinet walls and other components
Installing
5.3 Installing the converter
SINAMICS S210 servo drive system
88 Operating Instructions, 12/2017, A5E41702836B AA