EasyManuals Logo
Home>Siemens>Control Unit>SINUMERIK 808D

Siemens SINUMERIK 808D Commissioning Manual

Siemens SINUMERIK 808D
508 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #144 background imageLoading...
Page #144 background image
Commissioning Manual
144 01/2017
5.
After the sy
nchronization finishes successfully, the following dialog box displays on the
screen.
6.
Press this sof
tkey to exit the dialog box.
Checking the status LEDs on the SINAMICS V70 drives
When the data synchronization is completed, the LEDs on the drive indicate the drive is in ready state (
RDY
: green;
COM
:
slow flashing green every two seconds). The drive BOP displays S-off or a fault depending on the type of connected
encoder.
5.3
Setting the password
The control system provides a concept of protection levels for enabling data areas. Different protection levels control
different access rights.
The control system delivered from Siemens is set by default to the lowest protection level 7 (without password). If the
password is no longer known, you must reinitialize the control system with the default machine/drive data. All passwords are
then reset to default passwords for this software release.
Note
Before you boot
the control system with default machine/drive data, make sure that you have backed up your machine/drive
data; otherwise, all data are lost after rebooting with default machine/drive data.
Protection level
Locked by
Area
Access right
0
Siemens password
Siemens, reserved
-
1
Manufacturer password
(Default password:
"SUNRISE")
Machine manufacturers
• Entering or changing part of the machine data
and drive data
• Conducting NC and drive commissioning
2
Reserved
-
-
3-6
End-user password
(Default password:
"CUSTOMER")
End users
• Entering or changing part of the machine data
• Editing programs
• Setting offset values
•
Measuring tools
7 *
No password
End users
-
* Protection level 7 is set automatically if no password is set and no protection level interface s
ignal is set. The protection
level 7 can be set from the PLC user program by setting the bits in the user interface.

Table of Contents

Other manuals for Siemens SINUMERIK 808D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 808D and is the answer not in the manual?

Siemens SINUMERIK 808D Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 808D
CategoryControl Unit
LanguageEnglish

Related product manuals