Commissioning Manual
40 01/2017
Options
External 24 VDC Power Supply
The SINAMICS V60 drive unit should be connected to an external 24 VDC power supply. The following aspects should be
considered during selection of the 24 VDC supply.
● Rated input current: 2 A
● Rated voltage: 24 V (-15% to +20%)
Since the excellent quality of a DC power supply is critical to the stable operation of a drive system, Siemens recommends
you to select a Siemens 24 VDC stabilized power supply (article number: 6EP1333-3BA00). If there is no Siemens 24 VDC
power supply available, you can use a high-quality non-Siemens power supply instead.
A line filter is required so that the system can pass the CE certification (radiated emission test or conducted emission test).
The following aspects should be considered during selection of the filter.
● Rated current: 16 A
● Degree of protection: IP20
The filter recommended by Siemens has an article number of 6SN1111-0AA01-1BA1.
You can install a mains linear breaker to protect the system. Refer to the following for the selection of the circuit breaker.
● Rated current:
– 15 A for 7 A or 10 A version of the drive
– 10 A for 4 A or 6 A version of the drive
● Rated voltage: 250 VAC
SIMATIC PLC/SINAMICS V60 signal cable
It is recommended to use SIEMENS-designed SIMATIC PLC/SINAMICS V60 signal cable (length: 3 m) to connect SIMATIC
PLC and SINAMICS V60. This signal cable can be ordered with the article number of 6ES7298-2DS23-0XA0.
For more information about the Toolbox DVD, see Section "Toolbox DVD (Page 33)".