Edit PLC user program (828D only)
24.8 Loading modified PLC user program
Turning
Operating Manual, 01/2015, 6FC5398-8CP40-5BA2
895
Loading modified PLC user program
Download the project data into the PLC if some changes have been made to the project data
and a new PLC user program is available.
When the project data is loaded, the data classes are saved and loaded to the PLC.
Check whether the PLC is in Stop mode.
Note
PLC in RUN mode
If the PLC is in RUN mode, a corresponding message is displayed and the "Load in Stop"
and "Load i
n Run" softkeys appear.
With "Load in Stop", the PLC is set to Stop mode and the project is stored and loaded to the
CPU.
With "Load in Run", the loading operation is continued and the PLC project loaded to the
PLC. Only those data classes that have reall
y been changed are loaded, i.e. generally
r add-on tool is opened.
You have changed project data.
Press the "PLC Stop" softkey i
f the PLC is in the run mode.
Press the "Load to CPU" softkey to start the loading ope
ration.
All data classes are loaded.
When the PLC project has been loaded, press the "
PLC Start" softkey
to switch the PLC to Run mode.