Page 4-134 110XiIIIPlus Maintenance Manual 13185L-002 Rev. A 1/24/06
Section 4 Maintenance
RFID Reader Board
Remove the RFID Reader Board
1. Refer to RRP No. 1 on page 4-14. Turn the printer Off (O) and remove the power
cord. Disconnect the printer communications cable.
2. Refer to RRP No. 2 on page 4-16 and remove the electronics cover
3. Refer to Figure 4-93. Disconnect the reader board harness from J2 on the power PC
board assembly.
Figure 4-93. Remove and Install the Reader Board Assembly
4. Disconnect the antenna carrier assembly cable from the reader board assembly by
twisting it off.
5. Loosen and remove the three reader board assembly mounting screws. Retain the
mounting screws.
6. Remove the reader board assembly from the printer.
Note • RFID kits are available for Zebra Authorized Service Providers only.
Caution:
The printer electronics are susceptible to static discharge. Before proceeding, it
is highly recommended that the technician wear an antistatic wrist strap
connected to the printer chassis.
PCMCIA
Option Board
AC/DC
Power
PCB
P6
P25
P27
P8
P2
P1
P3
P32
P31
P19
P5
P10
Main Logic
PCB
RFID
Reader Board
Reader Board
Mounting Screws
Antenna Carrier
Assembly Connector
Reader Board
Harness Assembly

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zebra 110XiIII Plus Series and is the answer not in the manual?

Zebra 110XiIII Plus Series Specifications

General IconGeneral
BrandZebra
Model110XiIII Plus Series
CategoryPrinter
LanguageEnglish

Related product manuals