13185L-002 Rev. A 1/24/06 110XiIIIPlus Maintenance Manual Page 4-101
Maintenance Section 4
Twinax Communications Interface Board
Install Instructions
1. Refer to RRP No. 1 on page 4-14. Turn the power Off (O) and disconnect the AC
power cord. Disconnect any data cables.
2. RRP No. 2 on page 4-16 and remove the electronics cover.
3. Refer to Figure 4-70. At the rear of the printer, remove and retain the two screws
and the blank cover plate or existing interface board positioned next to the main
RS-232 and parallel interface connectors.
Note • To print a PrintServer II configuration label from your Zebra printer, a
4 in. wide by 6 in. long (100 mm wide by 150 mm long) label is recommended. If
the label is smaller, some information may print outside the label edges. Some
of the heading information on the right side of the label will not print. Refer to
Figure 4-66 for any missing data.
Caution:
The printer electronics are susceptible to static discharge. Before proceeding, it
is highly recommended that the technician wear an antistatic wrist strap
connected to the printer chassis.
Caution:
Unless indicated otherwise, turn the printer Off (O) and disconnect the printer
from the power source before performing the following maintenance.
Caution:
This installation must be performed by a qualified service technician.