Rockwell Automation Publication 2094-UM002G-EN-P - August 2016 301
Web Server Interface Appendix E
Data Logs Category
The Data Logs pages provides access to data that is logged by the drive for
future retrieval.
Temperatures
The Temperatures tab reports temperatures from the control module, power
module, and encoder.
Figure 138 - Data Logs>Temperatures Tab
Table 140 - Temperatures Features
Field Name Description
SERCOS
(2094-SE02F-M00-Sx)
EtherNet/IP
(2094-EN02D-M01-Sx)
-S0 -S1 -S0 -S1
Control Module Temperature A 2048-sample log of control module temperature sampled at 1-minute intervals.XXXX
Power Module Temperature A 2048-sample log of power module temperature sampled at 1-minute intervals.XXXX
Encoder Temperature A 2048-sample log of encoder temperature sampled at 1-minute intervals. XXXX
Firmware Change
A 16-sample non-volatile log of firmware updates. Each log entry stores the firmware
version, CIP time stamp, and local time stamp.
XXXX
Safety Configuration Change
A 16-sample non-volatile log of safety configuration changes. Each log entry stores the
signature, CIP time stamp, and local time stamp.
–X–X
Motor Connection
An 8-sample log of motor catalog number or serial number changes. Each log entry
stores the motor catalog number, motor serial number, CIP time stamp, and local time
stamp.
XXXX
Main Power Cycling
A 16-sample non-volatile log of main power cycle events. Each log entry stores the type
(on or off), CIP time stamp, and local time stamp.
XXXX
Power Module Connection
An 8-sample non-volatile log of power module catalog number or serial number
changes. Each log entry stores the power module catalog number, serial number, CIP
time stamp, and local time stamp.
XXXX