Authentication List Configuration
D-Link Unified Wired and Wireless Access System
Oct. 2015 Page 83
D-Link UWS User Manual
Creating an Authentication List
To create a new authentication list, use the following procedures.
1. Select Create from the Authentication List field. The page refreshes, and different fields are available.
2. In the Authentication List Name field, enter a name of 1 to 12 characters.
The name is not case sensitive, but it cannot include spaces.
3. Click Submit to create the name and display the Method fields for the new list.
You are now ready to configure the authentication list. By default, local is set as the initial authentication
method.
To retain the changes across a power cycle, you must perform a save.
Configuring an Authentication List
To modify an authentication list, use the following procedures.
1. Select an existing list from the Authentication List menu.
2. From the Method 1 field, select the initial login method.
3. If desired, select the additional subsequent login method.
4. Click Submit to apply the changes to the system.
To retain the changes across a power cycle, you must perform a save.
Deleting an Authentication List
Use the following procedures to remove an authentication login list from the configuration.
1. Select an existing list from the Authentication List menu.
2. Click Delete.
The delete will fail if the selected login list is assigned to any user (including the default user) for system
login or IEEE 802.1X port access control. You can only use this button if you have Read/Write access.