324 Recovering and Troubleshooting the Managed System
Viewing iDRAC6 Log
iDRAC6 Log is a persistent log maintained in iDRAC6 firmware. The log
contains a list of user actions (such as log in, log out, and security policy
changes) and alerts issued by iDRAC6. The log gets erased after iDRAC6
firmware update.
Where the System Event Log (SEL) contains records of events that occur in
the managed server, iDRAC6 Log contains records of events that occur in
iDRAC6.
To access iDRAC6 Log, perform the following steps:
• Click
System
→
Remote Access
→
iDRAC6
and
then click
Logs
→
iDRAC6
Log
.
iDRAC6 Log provides the information in Table 20-9.
Critical LinkT/FlexAddr: Link Tuning
sensor, device option ROM failed
to support link tuning or
FlexAddress (Mezz XX) was
asserted
This event is generated when
the PCI device Option ROM
for a NIC does not support
link tuning or the Flex
addressing feature
Critical LinkT/FlexAddr: Link Tuning
sensor, failed to program the
virtual MAC address
(<location>) was asserted
This event is generated when
the BIOS fails to program the
virtual MAC address on the
given NIC device
Critical I/O Fatal Err: Fatal IO Group
sensor, fatal IO error
(<location>)
This event is generated in
association with a CPU IERR
and indicates which device
caused the CPU IERR
Warning PCIE NonFatal Er: Non Fatal I/O
Group sensor, PCIe error
(<location>)
This event is generated in
association with a CPU IERR
Table 20-8. Server Status Screen (continued)
Severity Message Cause