CABIN
B2050, B2350, B2650, B3150, WSM
10-S17
[2] DISCHARGING, EVACUATING AND CHARGING
IMPORTANT
• When discharging, evacuating or charging the refrigerating system, be sure to observe the
"PRECAUTION AT REPAIRING REFRIGERANT CYCLE".
9Y1210982CAS0027US0
(1) Discharging the System
Discharging R134a Refrigerant
Prepare for the R134a refrigerant recovery and recycling
machine.
1. Connect low pressure side hose (blue) from the recovery and
recycling machine to LO pressure side charging valve (1) on the
compressor (3). Connect high pressure side hose (red) to HI
pressure side charging valve (2) on the compressor (3).
2. Follow the manufacturers instructions and discharge the
system.
IMPORTANT
• Use only R134a refrigerant recovery and recycling
machine. Eliminate mixing R134a equipment, refrigerant,
and refrigerant oils with R12 systems to prevent
compressor damage.
CAUTION
• Protect fingers with cloth against frostbite by refrigerant
when disconnecting the hose to the charging valve.
9Y1210982CAS0028US0
(1) LO Pressure Side Charging Valve
(2) HI Pressure Side Charging Valve
(3) Compressor
KiSC issued 03, 2014 A

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kubota WSM B2050 and is the answer not in the manual?

Kubota WSM B2050 Specifications

General IconGeneral
BrandKubota
ModelWSM B2050
CategoryTractor
LanguageEnglish

Related product manuals