1-4
Description
X = Not Required
* One CSM-4 circuit must be configured for alarm
transmission. In addition, depending on the local
authority having jurisdiction, additional circuits may
be required for Supervisory or Trouble transmission.
** Any one of these modules is sufficient as an
initiating device.
*** Only TRI-60, TRI-60R, TRI-60D, TRI-B6, TRI-B6R, and
TRI-B6D can be used as security devices.
**** Do not use NET-4s and NET-7s in the same system.
NOTES
a. See Silent Knight Model 5128/5129 Connections and
Ratings for NFPA 72 Central Station.
b. Refer to System MXL Wiring Diagram, P/N 575-095370
c. The MMB must be programmed by CSG-M for all
System configurations (See CSG-M Programming
Manual, P/N 315-090381).
d. UL 1076 requires a Model TSW-2 tamper switch and a
TSP-40 printer.
e. The batteries available are: BP-61, BTX-1, and BTX-2.
The BP-61 is a module consisting of four 6V, 15 AH
batteries. The BTX-1 batteries are a pair of 12V, 31 AH
batteries. The BTX-2 batteries are a pair of 12V, 55 AH
batteries. Actual battery size depends on System
configuration.
f. See Appendix C for Battery Calculations.
g. The PSR-1 is not listed for security.
h. The PIM-1 requires the connection of the RC-119
supervised printer. The TSP-40 is not required.
j. The CMI-300 is not listed for UL 1076 application.
k. Refer to the CSM-4 Installation Instructions (P/N
315-090854) for programming.
l. The MXL System is FM approved for proprietary
fire for Fire Alarms, Water Flow, Sprinkler
Supervisory Service and Intrinsically Safe Operation.
Minimum MXL Configuration To Meet NFPA 72, UL 1076, and NFPA 12A, 13, and 2001
MINIMUM MXL CONFIGURATION TO MEET NFPA 72, UL 1076, AND NFPA 12A, 13, AND 2001
Module Description
NFPA Minimum Quantity
Local Auxiliary
Remote
Station Proprietary
Central
Station
a
UL 1076
b
12A, 13, or
2001
l
MMB-1/-2
c
MXL Main Unit 1 1 1 1 1 1 1
MPS-6 Power Supply 1 1 1 1 1 1 1
MPS-12 Power Supply 1 1 1 1 1 1 1
MKB-2 Keyboard/Annunciator Panel 1 1 1 1 1 1 1
TSP-40 Logging Printer X X X 1 X 1
d
X
MOM-4 Optional Module Card Cage X 1 1 X X X X
CSM-4 Signal Module X 1
k
1 or 2*
k
XXX1
k
CZM-4 Conventional Zone Module ** ** ** ** ** X **
ALD-2I Analog Loop Driver ** ** ** ** ** *** **
CZM-1B6
Remote Conventional Zone
Module
** ** ** ** ** X **
 Batteries
e,f
1
e
1
e
1
e
1
e
111
e
TSW-2 Tamper Switch XXXXX1
d
X
PSR-1 Remote Power Supply X X X X X X
g
X
NET-4/-7Communication Interface****XXXXXXX
MOI-1/-7Voice and Annunciator DriverXXXXXXX
MOD-16 Output Driver XXXXXXX
MID-16 Inpout Module XXXXXXX
PIM-1 Peripheral Interface Module X X X 1
h
X1
h
X
CMI-300 MXL/CXL Interface X X X X X X
j
X
Technical Manuals Online! - http://www.tech-man.com
firealarmresources.com

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens Cerberus PYROTRONICS MXL and is the answer not in the manual?

Siemens Cerberus PYROTRONICS MXL Specifications

General IconGeneral
BrandSiemens
ModelCerberus PYROTRONICS MXL
CategoryControl Panel
LanguageEnglish