1-35
Description
ILI-1A Intelligent/Analog lonization
High Air-Velocity Detector
1
The ILI-1A is an intelligent/analog
ionization high air-velocity detector for
use in open areas, computer facilities,
and air ducts at altitudes of 0 to 4000
feet, with air velocities of 0 to 1200
feet per minute. It uses either a DB-3S
low profile mounting base, a DB-X3RS
mounting base with relay, or an
ADBI-60 audible base.
ILI-1AH Intelligent/Analog lonization
High Air-Velocity, High Altitude
Detector
1
The ILI-1AH is an intelligent/analog
ionization high air-velocity, high altitude
detector for use in open areas, com-
puter facilities, and air ducts at altitudes
of 3000 to 8000 feet, with air velocities
of 0 to 1200 feet per minute. It uses
either a DB-3S low profile mounting
base, a DB-X3RS mounting base with
relay, or an ADBI-60 audible base.
ILI-1B Intelligent/Analog lonization
Air-Duct Detector
1
The ILI-1B is an intelligent/analog ioniza-
tion detector for use in air duct applica-
tions at altitudes of 0 to 4000 feet, with
air velocities of 500 to 4000 feet per
minute. It uses either the AD-3I housing
or the AD-3XRI housing.
ILI-1BH Intelligent/Analog lonization
Air-Duct High Altitude Detector
1
The ILI-1BH is an intelligent/analog
ionization detector for use in air duct
applications at altitudes of 3000 to 8000
feet, with air velocities of 500-4000
feet per minute. It uses either the
AD-3I or AD-3XRI housing.
ILP-2 Intelligent/Analog
Photoelectric Detector
1,2
The ILP-2 is an intelligent/analog photo-
electric detector that can be used as an
area or duct detector [ILP-2(d)]. It uses
either a DB-3S low profile mounting
base, a DB-X3RS mounting base with
relay, an AD-3ILP or AD-3XRILP duct
housing, or an ADBI-60 audible base.
ILT-1 Intelligent Thermal Detector
The ILT-1 is an intelligent rate-compen-
sated/fixed-temperature type thermal
detector. It uses either a DB-3S low
profile mounting base, a DB-X3RS
mounting base with relay, or an
ADBI-60 audible base.
MSI-10/20 Intelligent Manual Station
The MSI-10/20 is an intelligent manual
station designed to interface with an
analog loop. The MSI can be flush
mounted or surface mounted using the
SB-5R mounting box.
MSI-10B/20B Intelligent Manual
Station
The MSI-10B/20B is an intelligent
manual station designed to interface
with an analog loop. The MSI-10B/20B
can be flush mounted or surface
mounted using the SB-5R mounting box.
MSI-B6F Intelligent Manual Station
The MSI-B6F is an intelligent manual
station designed to interface with an
analog loop. The MSI-B6F is a single-
action station; when used with the
MS-FD adapter, the MSI-B6F is a
double-action station. The MSI-B6F
can be flush mounted or surface
mounted using the MS-FB backbox.