eth oam modify
Modify E-OAM configuration for an interface.
SYNTAX:
eth oam modify ifname = <{}>
[state = <{disabled|enabled}>]
[max-pdu-rate = <number{1-100}>]
[mru = <number{64-1518}>]
[tx-timeout = <number{1-86400}>]
[ll-timeout = <number{1-86400}>]
[oui = <string>]
[vendor-code = <number or string>]
[mode = <{passive|active}>]
[unidirectional = <{disabled|enabled}>]
[loopback = <{disabled|enabled}>]
[link-event = <{disabled|enabled}>]
[var-response = <{disabled|enabled}>]
where:
ifname The interface for which to configure E-OAM. REQUIRED
state Enable/disable E-OAM. OPTIONAL
max-pdu-rate Maximum number of PDUs per second. OPTIONAL
mru Maximum Receive Unit. OPTIONAL
tx-timeout Transmission timeout. OPTIONAL
ll-timeout Local Lost Link timeout. OPTIONAL
oui OUI to be used in Information OAM PDUs (system OUI if
left blank).
OPTIONAL
vendor-code Vendor Specific Information. OPTIONAL
mode E-OAM operational mode. OPTIONAL
unidirectional E-OAM unidirectional capability. OPTIONAL
loopback E-OAM loopback capability. OPTIONAL
link-event E-OAM link event capability. OPTIONAL
var-response E-OAM variable response capability. OPTIONAL