Page #201 background imageLoading...
Page #201 background image
7-59
Catalyst 6500 Series Switch Software Configuration Guide—Release 8.7
OL-8978-04
Chapter 7 Configuring Spanning Tree
Configuring BPDU Skewing on the Switch
Console> (enable) show spantree mst config
Current (NVRAM) MST Region Configuration: 3 instances
Configuration Name:arthur Revision:23703
Instance VLANs
-------- --------------------------------------------------------------
0 1,31-4094
2 2-20
3 21-30
=======================================================================
NEW MST Region Configuration (Not committed yet) 4 instances
Configuration Name:arthur Revision:23703
Instance VLANs
-------- --------------------------------------------------------------
0 1,31-899,1000-4094
2 2-20
3 21-30
1400 900-999
=======================================================================
Edit buffer is locked by:Console (pid 143)
Console> (enable) clear spantree mst 1400 vlan 900-998
Edit Buffer modified.
Use 'set spantree mst config commit' to apply the changes
Console> (enable) set spantree mst config commit
Console> (enable) show spantree mst config
Current (NVRAM) MST Region Configuration: 4 instances
Configuration Name:arthur Revision:23703
Instance VLANs
-------- --------------------------------------------------------------
0 1,31-998,1000-4094
2 2-20
3 21-30
1400 999
=======================================================================
Console> (enable)
Configuring BPDU Skewing on the Switch
Commands that support the spanning-tree BPDU skewing allow you to perform these functions:
Enable or disable BPDU skewing. The default is disabled.
Modify the show spantree summary output to show if the skew detection is enabled and for which
VLANs or PVST+ or MISTP instances the skew was detected.
Provide a display of the VLAN, PVST+, or MISTP instance and the port that is affected by the skew,
including this information:
The last skew duration (in absolute time)
The worst skew duration (in absolute time)
The date and time of the worst duration
To change how spanning tree performs BPDU skewing statistics gathering, enter the set spantree
bpdu-skewing command. The bpdu-skewing command is disabled by default.
To configure the BPDU skewing statistics gathering for a VLAN, perform this task in privileged mode: