Main Machine Installation
D255/D256/M281/M282 2-14 SM
2.2.6 SETTINGS ACCORDING TO THE SERVICE CONTRACT
Change the necessary settings depending on the customer's service contract.
Meter Click Charge
There are two ways to set up this function.
ï‚§ Meter click charge enabled (SP5-930-001 set to "1 (enabled)"; this is the default
setting): The counter can be displayed and printed by the customer. The service
representative can then call the customer and ask for the counter.
ï‚§ Meter click charge disabled (SP5-930-001 set to "0 (disabled)"): The counter cannot be
displayed or printed by the customer. To check the counter, the service representative must
print the SMC report (SP 5-990).
Item SP No. Function Default
Meter Click Charge SP5-930-001
Enables or disables Meter Click
Charge.
When enabled:
ï‚§ The counter menu shows
immediately after you push the
"Menu" key.
In MP 501/601, "Counter Method"
(SP5-045-001) sets the type of
the counter.
ï‚§ You can print the counter from the
counter menu.
When disabled:
ï‚§ The counter menu does not show.
1: ON
Meter Click Charge:
Maintenance Kit
SP5-931-001
Enables or disables the PM alert for
the maintenance kit.
* This setting is unnecessary with this
machine since this machine does not
have the maintenance kit.
1: No
alert