REMOTE INTERFACE
311
SOURce[1|2|3|3RF]:PM:STATe
Turns PM Modulation on or off. By default PM
modulation is off.
Burst or sweep mode will be disabled if PM
modulation is enabled. As only one modulation is
allowed at any one time, other modulation modes
will be disabled when PM modulation is enabled.
SOURce[1|2|3|3RF]:PM:STATe {OFF|ON}
SOURce[1|2|3|3RF]:PM:STATe?
PM modulation is currently enabled.
SOURce[1|2|3|3RF]:PM:SOURce
Sets or queries the PM source as internal or
external. Internal is the default source.
If an external PM source is selected, the phase
modulation is controlled by the MOD INPUT
terminal on the rear panel.
The RF channel supports only the internal
modulation mode.
SOURce[1|2|3|3RF]:PM:SOURce {INTernal|EXTernal}
Sets the PM source to internal.
SOURce[1|2|3|3RF]:PM:SOURce?