MFG-2000 Series User Manual
328
4. Choose Linear or Logarithmic spacing using
the SOURce[1|2|3|3RF]:SWE:SPAC
command.
Select Sweep Time
Select the sweep
trigger source
Select the marker
frequency
5. Choose the sweep time using the
SOURce[1|2|3|3RF]:SWE:TIME command.
6. Select an internal or external sweep trigger
source using the SOURce[1|2|3|3RF]:SOUR
command.
7. To output a marker frequency from the trigger
out, use The SOURce[1|2]:MARK:FREQ
command. To enable marker frequency
output, use the SOURce[1|2]:MARK ON
command.
The marker frequency can be set to a value
within the sweep span.
SOURce[1|2|3|3RF]:SWEep:STATe
Sets or disables Sweep mode. By default Sweep is
disabled. Sweep modulation must be enabled
before setting other parameters.
Any modulation modes or Burst mode will be
disabled if sweep mode is enabled.
SOURce[1|2|3|3RF]:SWEep:STATe {OFF|ON}
SOURce[1|2|3|3RF]:SWEep:STATe?