REMOTE INTERFACE
353
Syntax
SOURce[1|2|3]:ARB:EDIT:UNProtect
Example
SOUR1:ARB:EDIT:UNP
SOURce[1|2|3]:ARB:NCYCles
Source Specific
Command
Description
The arbitrary waveform output can be repeated
for a designated number of cycles.
Syntax
SOURce[1|2|3]:ARB:NCYCles {< #cycles>
|INFinity|MINimum |MAXimum}
Parameter
<# cycles>
1~16384 cycles
INFinity
Sets the number of cycles
to continuous.
MINimum
Sets the number of cycles
to the minimum allowed.
MAXimum
Sets the number of cycles
to the maximum allowed.
Example
SOUR1:ARB:NCYC INF
Sets the number of ARB waveform output cycles
to continuous (infinite).
Query Syntax
SOURce[1|2|3]:ARB:NCYCles? [MINimum|MAXimum]
Return Parameter
<NR3>
Returns the number of cycles.
INF
INF is returned if the number of cycles
is continuous.
Example
SOUR1:ARB:NCYC?
+1.0000E+02
The number of ARB waveform output cycles is
returned (100).
SOURce[1|2]:ARB:OUTPut:MARKer
Source Specific
Command
Description
Define a section of the arbitrary waveform for
marker output. The marker is output from the
trigger terminal on the rear panel.

Table of Contents

Other manuals for GW Instek MFG-2000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GW Instek MFG-2000 Series and is the answer not in the manual?

GW Instek MFG-2000 Series Specifications

General IconGeneral
BrandGW Instek
ModelMFG-2000 Series
CategoryInverter
LanguageEnglish

Related product manuals