February 2012 31 – 607
31.4.8 Configuration of the data interface
MP Function and input Software
version and
behavior
MP5000 Disable data interfaces
Input: 0: No interface disabled
1: RS-232-C/V.24 interface disabled
2: RS-422/V.11 interface disabled
3: RS-232-C/V.24 and RS-422/V.11 interfaces disabled
PLC
RUN
MP5020 Configuration of the data interface
Format: %xxxxxxxx
Input: Bit 0 –
0: 7 data bits
1: 8 data bits
Bit 1 –
0: Any BCC character
1: BCC not control character
Bit 2 –
0: Transmission stop by RTS not active
1: Active
Bit 3 –
0: Transmission stop by DC3 not active
1: Active
Bit 4 –
0: Character parity even
1: Odd
Bit 5 –
0: Character parity not desired
1: Desired
Bit 6 = 0, Bit 7 = 0: 1.5 stop bits
Bit 6 = 1, Bit 7 = 0: 2 stop bits
Bit 6 = 0, Bit 7 = 1: 1 stop bit
Bit 6 = 1, Bit 7 = 1: 1 stop bit
Bit 8, 9 – Reserved
Bit 10 –
Check for missing connection
0: Active
1: Not active
PLC
RUN
CN123
MP5020.0 Operating mode EXT1
MP5020.1 Operating mode EXT2
MP5020.2 Operating mode EXT3 (PLC)
MP5020.3 Operating mode EXT4 (PLC)
MP5030 Communications protocol
Input: 0 = Standard data transfer
1 = Blockwise transfer
2 = Without protocol (only for MP5030.2)
PLC
RUN
CN123
MP5030.0 Operating mode EXT1
MP5030.1 Operating mode EXT2
MP5030.2 Operating mode EXT3 (PLC)
MP5030.3 Operating mode EXT4 (PLC)

Table of Contents

Other manuals for HEIDENHAIN iTNC 530 HSCI

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HEIDENHAIN iTNC 530 HSCI and is the answer not in the manual?

HEIDENHAIN iTNC 530 HSCI Specifications

General IconGeneral
BrandHEIDENHAIN
ModeliTNC 530 HSCI
CategoryControl Systems
LanguageEnglish

Related product manuals