February 2012 8 – 83
8.4 Overview of log entries
Entry Description
RESET Restart the control
ERR Error messages
îš„ P
--> PLC error message with the line number in the PLC error text file
îš„ N
--> NC error message with number
îš„ Power fail interrupt!
--> The control was switched off by a POWERFAIL.
îš„ Result of the file system test:
If the control is not properly shut down, the file system is checked during
the next startup and the result is entered in the log.
--> Search for "dosfsck" in the log.
INFO "xxx" "xxx": Name of the control process that enters the information in the log
îš„ PLC
îš„ SYS
îš„ MAIN
îš„ REMO
îš„ CTRL
îš„ SMARTNC
îš„ SMARTNC_LDF
îš„ BDEHAN
îš„ SOKY
îš„ GEO
îš„ PYTHON
îš„ FIXTURE
îš„ FILEMAN
INFO CTRL KINEMATIC Active tool with tool number, radius (R=) and length (L=)
INFO CTRL collision Status of collision monitoring in the Manual and Automatic operating modes
INFO CTRL REG
AXIS xx START REF=yy
Position yyyy of axis xx at start of movement
INFO CTRL REG
AXIS xx STOP REF=yy
Position yyyy of axis xx at stop of movement
INFO MAIN ERRCLEARED Acknowledgment of an error message
INFO MAIN ERR_RECURED Error message entered several times
INFO MAIN ENDAT Entry for the position upon switch-on, if the switch-off and switch-on positions
of an EnDat encoder do not match
INFO MAIN RUNPROC Status information about the current process
KEY Keystrokes
INFO MAIN SOFTKEY Path with associated image file of a pressed soft key
Control-in-
operation
a
ON Control-in-operation on
OFF Control-in-operation off
BLINK Control-in-operation symbol blinking
a. Control-in-operation symbol = " * " in the screen display