Section
8: TSP command reference Model 2450 Interactive SourceMeter® Instrument Ref
erence Manual
8-4 2450-901-01 Rev. B/September 2013
The subsections contain information about the command. The subsections are:
Command name, brief description, and summary table
Usage
Details
Example
Also see
The content of each of these subsections is described in the following topics.
Command name, brief description, and summary table
Each instrument command description starts with the command name, followed by a brief description
and a table with information for each command. Definitions for the numbered items in the figure below
are listed following the figure.
Figure 137: TSP command name and summary table
1 Instrument command name. Indicates the beginning of the command description. It is followed
by a brief description of what the command does.
2 Type of command. Commands can be functions, attributes, or constants. If the command is an
attribute, it can be read-only (R), read-write (RW), or write-only (W). For detail about commands,
see Introduction to TSP operation (on page 7-1
).
3 TSP-Link accessible. Indicates whether or not the command can be accessed through a TSP-
Link network (Yes or No).
4 Affected by. This columns lists commands or actions that can change the value of the command.
These include the following actions.
Power cycle: The command settings are not saved through a power cycle.
Restore configuration: If you restore a configuration script, this setting changes to the stored setting.
Instrument reset: When you reset the instrument, this command is reset to its default value. Reset can
be done from the front panel or when you send reset(), localnode.reset(), or *RST.
Source configuration list: If you recall a source configuration list, this setting changes to the stored
setting.
Measure configuration list: If you recall a measure configuration list, this setting changes to the stored
setting.
Function: This command changes value when the function is changed (for example, changing from a
voltage source to a current source or changing from a current measurement to a resistance
measurement).

Table of Contents

Other manuals for Keithley 2450

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keithley 2450 and is the answer not in the manual?

Keithley 2450 Specifications

General IconGeneral
BrandKeithley
Model2450
CategoryTest Equipment
LanguageEnglish

Related product manuals