155
4.4 Error Code
REGIUS MODEL 190 Service Manual Ver.1.00 2004.11.01
4.4.3 Mechanical Control Error Code (04101 ~ 04106)
04101 ~ 04106 indicates an error occurred on the motors.
Error
code
Error name Error description Action
04101
Subscan motor NG A deviation occurred between the
elevation pulse number and the
descent pulse number (i.e., HP
motion) during initialization opera-
tions for subscanning.
Check MCB2:CN5-, pins 16 through 18
(Subscan HP Sensor) and MCB2:CN6
(Subscan Motor)
04102
Transportation Motor
NG
A deviation occurred between the
pulse number for [insertion posi-
tion -->Escape Position motion]
and the pulse number for [Escape
Position --> insertion position
motion] during initialization opera-
tions for the Transport Unit.
Check MCB2:CN11-, pins 32 through 34
(Feed HP sensor); MCB2:CN11-, pins
35 through 37 (Feed excape position
sensor); and MCB2:CN15 (Transporta-
tion Motor)
04103
Elevator motor NG A deviation occurred between the
descent pulse number and the
elevation pulse number (i.e., HP
motion) during initialization opera-
tions for the elevation bed.
Check MCB2:CN11-, pins 26 through 28
(Elevator HP Sensor) and MCB2:CN16
(Elevator Motor)
04104
Justification motor NG A deviation occurred between the
closing-direction pulse number
and the opening-direction pulse
number (i.e., HP motion) during
initialization operations for justifi-
cation.
Check MCB2:CN11-, pins 29 through 31
(Justification HP Sensor) and
MCB2:CN17 (Justification Motor)
04105
Insertion shutter open/
close time-out
A time out occurred due to lack of
response from the sensor upon
opening or closing of the installa-
tion port shutters.
Check MCB2:CN10-, pins 11 through 13
(Insertion Shutter Open Sensor);
MCB2:CN10-, pins 14 through 16 (shut-
ter closed sensor); and MCB2:CN10-,
pins 3 through 4 (Shutter Motor)
04106 Lock time-out A time out occurred due to lack of
response from the sensor upon
locking.
• Check MCB2:CN11-, pins 3 through
5 (Lock Release Sensor) and
MCB2:CN11-, pins 1 and 2 (Lock
Release Motor)
• Check the plunger pin is actuating. if
it is not smoothly action
ig, replace
the cassette receive unit. (p.54)