158
4.4 Error Code
REGIUS MODEL 190 Service Manual Ver.1.00 2004.11.01
4.4.5 Mechanical Control Error Code (04200 ~ 04219)
04200 ~ 04219 indicates an error relating the SCB2 communication.
Error
code
Error name Error description Action
04200 GetStatus receipt
time-out - Initialize
Initialize Communication for the
purpose of reporting the start of
initialization to the SCB2 was not
possible.
Open the front door, remove any cas-
sette that may be present inside the
equipment, and then carry out a restart.
If this problem should reoccur, confirm
that the SCB2(CN5)-MCB2(CN4) con-
nectors are connected and that cables
are not damaged or broken.
04201 GetStatus receipt
time-out - Ready
Ready Communication for the
purpose of reporting either the
completion of initialization or cas-
sette ejection to the SCB2 was
not possible.
Open the front door, remove any cas-
sette that may be present inside the
equipment, and then carry out a restart.
If this problem should reoccur, confirm
that the SCB2(CN5)-MCB2(CN4) con-
nectors are connected and that cables
are not damaged or broken.
04202 GetStatus receipt
time-out - Barcode
detect
Barcode detection Communica-
tion for the purpose of reporting
bar code detection to the SCB2
was not possible.
Open the front door, remove any cas-
sette that may be present inside the
equipment, and then carry out a restart.
If this problem should reoccur, confirm
that the SCB2(CN5)-MCB2(CN4) con-
nectors are connected and that cables
are not damaged or broken.
04203 GetStatus receipt
time-out - high voltage
ON
High-voltage on Communication
for the purpose of reporting a
request for high-voltage to the
SCB2 was not possible.
Open the front door, remove any cas-
sette that may be present inside the
equipment, and then carry out a restart.
If this problem should reoccur, confirm
that the SCB2(CN5)-MCB2(CN4) con-
nectors are connected and that cables
are not damaged or broken.
04204 GetStatus receipt
time-out - laser ON
Laser on Communication for the
purpose of reporting a request for
Laser On to the SCB2 was not
possible.
Open the front door, remove any cas-
sette that may be present inside the
equipment, and then carry out a restart.
If this problem should reoccur, confirm
that the SCB2(CN5)-MCB2(CN4) con-
nectors are connected and that cables
are not damaged or broken.
04205 GetStatus receipt
time-out - bar code
delete
Bar Code erasure Communica-
tion for the purpose of reporting a
request for cassette draw-out to
the SCB2 was not possible.
Open the front door, remove any cas-
sette that may be present inside the
equipment, and then carry out a restart.
If this problem should reoccur, confirm
that the SCB2(CN5)-MCB2(CN4) con-
nectors are connected and that cables
are not damaged or broken.
04206 GetStatus receipt
time-out - Processing
Processing Communication for
the purpose of reporting process-
ing of a cassette to the SCB2 was
not possible.
Open the front door, remove any cas-
sette that may be present inside the
equipment, and then carry out a restart.
If this problem should reoccur, confirm
that the SCB2(CN5)-MCB2(CN4) con-
nectors are connected and that cables
are not damaged or broken.