EasyManua.ls Logo

Konica Minolta REGIUS 190 - Mechanical Control Error Code (04200 ~ 04219)

Konica Minolta REGIUS 190
220 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
158
4.4 Error Code
REGIUS MODEL 190 Service Manual Ver.1.00 2004.11.01
4.4.5 Mechanical Control Error Code (04200 ~ 04219)
04200 ~ 04219 indicates an error relating the SCB2 communication.
Error
code
Error name Error description Action
04200 GetStatus receipt
time-out - Initialize
Initialize Communication for the
purpose of reporting the start of
initialization to the SCB2 was not
possible.
Open the front door, remove any cas-
sette that may be present inside the
equipment, and then carry out a restart.
If this problem should reoccur, conrm
that the SCB2(CN5)-MCB2(CN4) con-
nectors are connected and that cables
are not damaged or broken.
04201 GetStatus receipt
time-out - Ready
Ready Communication for the
purpose of reporting either the
completion of initialization or cas-
sette ejection to the SCB2 was
not possible.
Open the front door, remove any cas-
sette that may be present inside the
equipment, and then carry out a restart.
If this problem should reoccur, conrm
that the SCB2(CN5)-MCB2(CN4) con-
nectors are connected and that cables
are not damaged or broken.
04202 GetStatus receipt
time-out - Barcode
detect
Barcode detection Communica-
tion for the purpose of reporting
bar code detection to the SCB2
was not possible.
Open the front door, remove any cas-
sette that may be present inside the
equipment, and then carry out a restart.
If this problem should reoccur, conrm
that the SCB2(CN5)-MCB2(CN4) con-
nectors are connected and that cables
are not damaged or broken.
04203 GetStatus receipt
time-out - high voltage
ON
High-voltage on Communication
for the purpose of reporting a
request for high-voltage to the
SCB2 was not possible.
Open the front door, remove any cas-
sette that may be present inside the
equipment, and then carry out a restart.
If this problem should reoccur, conrm
that the SCB2(CN5)-MCB2(CN4) con-
nectors are connected and that cables
are not damaged or broken.
04204 GetStatus receipt
time-out - laser ON
Laser on Communication for the
purpose of reporting a request for
Laser On to the SCB2 was not
possible.
Open the front door, remove any cas-
sette that may be present inside the
equipment, and then carry out a restart.
If this problem should reoccur, conrm
that the SCB2(CN5)-MCB2(CN4) con-
nectors are connected and that cables
are not damaged or broken.
04205 GetStatus receipt
time-out - bar code
delete
Bar Code erasure Communica-
tion for the purpose of reporting a
request for cassette draw-out to
the SCB2 was not possible.
Open the front door, remove any cas-
sette that may be present inside the
equipment, and then carry out a restart.
If this problem should reoccur, conrm
that the SCB2(CN5)-MCB2(CN4) con-
nectors are connected and that cables
are not damaged or broken.
04206 GetStatus receipt
time-out - Processing
Processing Communication for
the purpose of reporting process-
ing of a cassette to the SCB2 was
not possible.
Open the front door, remove any cas-
sette that may be present inside the
equipment, and then carry out a restart.
If this problem should reoccur, conrm
that the SCB2(CN5)-MCB2(CN4) con-
nectors are connected and that cables
are not damaged or broken.