• Speakerphone – displays only when a system is paired with SoundStation IP 7000
conference phone. If the Enable Audio-Only Calls checkbox is cleared, the audio dial
preference settings are not displayed.
4. Click Save.
Place an Audio-Only Call from the System Web Interface
You can place audio-only calls from the RealPresence Group Series system web interface.
Procedure
1. In the system web interface, go to Place a Call > Manual Dial.
2. Select audio.
3. To place the call, do one of the following:
4. Enter the number and click Call.
5. Under Recent Calls, click the desired audio call.
Enable Show Content in Audio-Only Call
In an audio-only call, this feature allows you to view the content instead of the video mute image in the
RealPresence Group Series system.
This feature is applicable only for calls between:
• RealPresence Group Series system to Skype for Business client.
• RealPresence Group Series AVMCU calls.
Procedure
1. In the system web user interface, go to Admin Settings > Audio/Video > Monitors .
2. For Monitor 1 at Monitor Profile select Far, then Content, then Near.
3. Select the Show Content if Far Video is Not Available check box.
4. Click Save.
Displaying Participant Names Continuously in a Call
Administrators can configure a system to display participant names throughout a conference call.
This setting is available on RealPresence Group Series 500 and 700 systems for multipoint calls only.
Configure Participant Name Display
You can allow participants in a multipoint call to see participant names throughout the call.
Procedure
1. In the system web interface, go to Admin Settings > General Settings > System Settings >
Call Settings.
2. At Display Participant Names in Multipoint Video, select one of the following:
• Auto: After participants join a call, their names are displayed for 10 seconds (default).
• Always: Participant names are displayed throughout a call.
Configuring Call Settings
Polycom, Inc. 129