772 Data Collection and Analysis
8. Disconnect the cradle before pressing the OK in the message box.
9. When the TI-Nspire™ Lab Cradle is disconnected from the handheld
or computer, verify the status. When the LED transfer is blinking
amber it is ready and waiting.
10. When you are at the site to collect the data, click the trigger button
on the lab cradle. The data collection will start immediately.
After you have collected your data see Retrieving data from remote
data collection.
Using a delay to start the collection
1. Save and close any open documents.
When performing experiments it is recommended that you have only
one document open. The system cannot determine which of the
documents to use with the sensor if multiple documents are open.
2. Attach sensor to the TI-Nspire™ Lab Cradle.
3. Attach the TI-Nspire™ Lab Cradle to the computer or handheld.
4. Set up your experiment as desired.
5. Navigate to Experiment > Advanced Set Up > Remote Collection
> TI-Nspire Lab Cradle.
6. Review the settings. Specify the time (in seconds) to delay the start of
the collection.

Table of Contents

Other manuals for Texas Instruments TINSPIRE

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Texas Instruments TINSPIRE and is the answer not in the manual?

Texas Instruments TINSPIRE Specifications

General IconGeneral
BrandTexas Instruments
ModelTINSPIRE
CategoryCalculator
LanguageEnglish

Related product manuals