58 EN 3340.758.003a - 2014-11
INSTALLATION
MM9000 Rev C.8 01/13 Page 58
MM9000 ClearCommand User Manual
Installation
4.4 Hard-Wired Cable
Liquid Tight Connector All cables that enter the Enclosure must go through a Liquid Tight Connector
in order to maintain the moisture resistant integrity of the Processor. These connectors must be
assembled as shown in Figure 4-4: Liquid Tight Installation
Figure 4-4: Liquid Tight Installation
4.4.1 Standard Processor Cable Holes
1. When hard-wiring a Processor or installing additional Station pigtails, the cables must enter
the enclosure through Liquid Tight Connectors in the appropriate holes as shown in Figure 4-
5: Standard Enclosure Cable Holes
Station 5
2. Station 3
3. Station 1
4. Alarm, Clutch Pressure, and Start Interlock
5. Power
6. Station 4
7. Station 2
8. Serial Communication
9. Tachometer
Figure 4-5: Standard Enclosure Cable Holes
4.4.2 Standard Circuit Board Connections
On a Standard Processor, in lieu of using Harnesses for Control Heads, Power, Serial Communication
and Tachometer, the Processor can be ordered with no pigtails installed. The above connections then
must be hard-wired directly to the circuit board
On Standard Processors using pigtails, additional Stations may also be connected to the Processor by
connecting pigtails or hard-wiring directly to the circuit board.
Cable
Securing Nut
Grommet
Body
Processor
Enclosure
Nut
12278_ART