EasyManuals Logo
Home>Keithley>Test Equipment>2450

Keithley 2450 User Manual

Keithley 2450
878 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #307 background imageLoading...
Page #307 background image
Section
4: Source-measure considerations Model 2450 Interactive SourceMeter® Instrument
Reference Manual
4-28 2450-901-01 Rev. B/September 2013
Buffer reset values
Setting Default value on
reset
Not available from front panel
:TRACe:FILL:MODE (on page 6-112
)
bufferVar.fillmode (on page 8-19)
Default buffers:
Continuous
User-defined
buffers: Once
Not available from front panel
:TRACe:LOG:STATe (on page 6-113
)
bufferVar.logstate (on page 8-22)
Default buffers: ON
User-created
buffers: OFF
Trigger reset values
Setting Default value on
reset
Not available from front panel
:TRIGger:BLENder<n>:MODE (on page 6-125)
trigger.blender[N].orenable (on page 8-166)
AND
Not available from front panel
:TRIGger:DIGital<n>:IN:EDGE (on page 6-150)
trigger.digin[N].edge
Falling edge
Not available from front panel
:TRIGger:DIGital<n>:OUT:LOGic (on page 6-151)
trigger.digout[N].logic (on page 8-174)
Positive
Not available from front panel
:TRIGger:DIGital<n>:OUT:PULSewidth (on page 6-152
)
trigger.digout[N].pulsewidth (on page 8-174)
10e-6
Not available from front panel
:TRIGger:DIGital<n>:OUT:STIMulus (on page 6-153
)
trigger.digout[N].stimulus (on page 8-175)
None
Not available from front panel
:TRIGger:LAN<n>:IN:EDGE (on page 6-155)
trigger.lanin[N].edge (on page 8-177)
Either edge
Not available from front panel
:TRIGger:LAN<n>:OUT:IP:ADDRess (on page 6-158)
trigger.lanout[N].ipaddress (on page 8-182)
0.0.0.0
Not available from front panel
:TRIGger:LAN<n>:OUT:PROTocol (on page 6-159)
trigger.lanout[N].protocol (on page 8-183)
TCP
Not available from front panel
:TRIGger:LAN<n>:OUT:STIMulus (on page 6-159
)
trigger.lanout[N].stimulus (on page 8-184)
None
Not available from front panel
:TRIGger:TIMer<n>:COUNt (on page 6-167
)
trigger.timer[N].count (on page 8-216)
1
Not available from front panel
:TRIGger:TIMer<n>:DELay (on page 6-168)
trigger.timer[N].delay (on page 8-217)
10e-6
Not available from front panel
:TRIGger:TIMer<n>:STARt:FRACtional (on page 6-169)
trigger.timer[N].start.fractionalseconds (on page 8-221)
0

Table of Contents