Checkyoure xternalsonarmodule’snetworkandpowerconnection,checkyourMFD’snetworkor
transducerconnectionensuringtheconnectionsandcablingiscorrectandfreefromdamage,
thenpowercycleyoursystem.IftheSonarmoduleisstillnotfoundthenrefertoyourequipment’s
installationdocumentationforfurthertroubleshootinginformation.
Notransducerconnected
IftheNotransducerconnectedwarningisdisplayedthenyourSonarmodulecannotconnectto
yourtransducer.
Checkyourtransducerconnection(s)arecorrectandfreefromdamage ,thenpowercycleyour
system.Ifthetransducerisstillnotfoundthenrefertoyourequipment’sinstallationdocumentation
forfurthertroubleshootinginformation.
11.3Sonarchannels
TheSonarchannelsthatareavailabledependontheSonarmoduleandtransduceryouhave
connected.
R ealVision3D SideVision DownVision
HighCHIRP/HighFrequency MediumCHIRP/Medium
Frequency
LowCHIRP/LowFrequency