23.3P
oweruptroubleshooting
Productdoesnotturnonorkeepsturningoff
P
ossiblecausesPossiblesolutions
Blownfuse/tripped
break
er.
1.Checkconditionofrelevantfusesandbreakersandconnections,
replaceifnecessary.(RefertotheT echnicalSpecificationsectionof
yourproduct’sinstallationinstructionsforfuseratings.)
2.Iffusekeepsblowingcheckforcabledamage,brokenconnectorpins
orincorrectwiring.
P oor/damaged/
insecurepowersupply
cable/connections
1.Checkthatthepowercableconnectoriscorrectlyorientatedandfully
insertedintothedisplayconnectorandlockedinposition.
2.Checkthepowersupplycableandconnectorsforsignsofdamageor
corrosion,andreplaceifnecessary.
3.Withthedisplayturnedon,tryflexingthepowercableneartothe
displayconnectortoseeifthiscausestheunittorestartorlose
power.Replaceifnecessary.
4.Checkthevessel’sbatteryvoltageandtheconditionofthebattery
terminalsandpowersupplycables,ensuringconnectionsaresecure,
cleanandfreefromcorrosion.Replaceifnecessary.
5.Withtheproductunderload,usingamulti-meter,checkforhigh
voltagedropacrossallconnectors/fusesetc,andreplaceif
necessary.
Incorrectpower
connection
Thepowersupplymaybewiredincorrectly ,ensuretheinstallation
instructionshavebeenfollowed.
Productwillnotstartup(restartloop)
P ossiblecausesPossiblesolutions
P owersupplyand
connection
Seepossiblesolutionsfromthetableabove,entitled‘Productdoesnot
turnonorkeepsturningoff.
Softwarecorruption1.Intheunlik elyeventthattheproduct’ssoftwarehasbecome
corrupted,trydownloadingandinstallingthelatestsoftwarefromthe
Raymarinewebsite.
2.Ondisplayproducts,asalastresort,attempttoperforma‘Power
onReset’.Beawarethatthiswilldeleteallsettings/presetsand
userdata(suchaswaypointsandtracks),andreverttheunitback
tofactorydefaults.
Warning:Factoryresetwarning
Performingafactoryresetwillrestoreallsystemandappsettingstofactory
defaultsanderasealluserdata(suchaswaypoints,routes,tracks,camera
recordingsandphotos).
P erformingapoweronresetAxiom™
Important:
Beforeperformingapoweronresetensureyouhaveback edupyoursettingsanduserdata
(waypoints,routesandtracks)toamemorycard.
Y oumayalsowanttosaveanycrashlogsthatarestoredonyourMFDtomemorycardfor
futurereference..
1.S witchoffpoweratthebreakertoensurethattheMFDiscompletelypoweredoff,andnotin
Standbymode.Alternatively,removethepowercablefromthedisplay.
T roubleshooting
407

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Raymarine LIGHTHOUSE 3 and is the answer not in the manual?

Raymarine LIGHTHOUSE 3 Specifications

General IconGeneral
BrandRaymarine
ModelLIGHTHOUSE 3
CategoryMarine Equipment
LanguageEnglish

Related product manuals