InteliLite 9 Global Guide
244
Setpoint group Basic settings Related FW 1.1.0
Range [units] 45 .. 65 [Hz]
Default value 50 Hz Alternative config YES
Step 1 Hz
Comm object 9914 Related applications AMF, MRS
Config level Standard
Setpoint visibility Always
Description
Nominal system frequency (usually 50 or 60 Hz).
Note: This value is used when binary input ALTERNATE CONFIG 2 (PAGE 295) is active.
Nominal Frequency 2
6 back to List of setpoints
Setpoint group Basic settings Related FW 1.1.0
Range [units] 80 .. 20000 [V]
Default value 231 V Alternative config YES
Step 1 V
Comm object 12053 Related applications AMF, MRS
Config level Standard
Setpoint visibility
Conditioned by the setpoint Connection type 2 (page 246).
Description
Nominal system voltage (phase to neutral).
Note: This value is used when binary input ALTERNATE CONFIG 2 (PAGE 295) is active.
Nominal Voltage Ph-N 2
6 back to List of setpoints
Setpoint group Basic settings Related FW 1.1.0
Range [units] 80 .. 40000 [V]
Default value 400 V Alternative config YES
Step 1 V
Comm object 12056 Related applications AMF, MRS
Config level Standard
Setpoint visibility
Conditioned by the setpoint Connection type 2 (page 246).
Description
Nominal system voltage (phase to phase).
Note: This value is used when binary input ALTERNATE CONFIG 2 (PAGE 295) is active.
Nominal Voltage Ph-Ph 2
6 back to List of setpoints