238 ISO Programming
4.13 Zero Point Shifts
Absolute zero point shift G59
G59 sets the workpiece zero point to X, Z. The new zero point remains
in effect to the end of the program.
Example: G59
. . .
N1 G59 Z256 [zero point shift]
N2 G14 Q0
N3 T3 G95 F0.25 G96 S200 M3
N4 G0 X62 Z2
. . .
Parameters
X Displacement (shift) (radius)
Z Displacement (shift)
G59 cancels all previous zero point shifts (with G51, G56
or G59).