259
timer lsp-max-age
Use timer lsp-max-age to set the LSP maximum age in the LSDB.
Use undo timer lsp-max-age to restore the default.
Syntax
timer lsp-max-age seconds
undo timer lsp-max-age
Default
The LSP maximum age is 1200 seconds.
Views
IS-IS view
Predefined user roles
network-admin
Parameters
seconds: Specifies the LSP maximum aging time in the range of 1 to 65535 seconds.
Usage guidelines
Each LSP has an age that decreases in the LSDB. Any LSP with an age of 0 is deleted from the LSDB. You
can adjust the age value based on the scale of a network.
Examples
# Set the maximum LSP age to 1500 seconds.
<Sysname> system-view
[Sysname] isis 1
[Sysname-isis-1] timer lsp-max-age 1500
Related commands
timer lsp-refresh
timer lsp-refresh
Use timer lsp-refresh to configure the LSP refresh interval.
Use undo timer lsp-refresh to restore the default.
Syntax
timer lsp-refresh seconds
undo timer lsp-refresh
Default
The default LSP refresh interval is 900 seconds.
Views
IS-IS view

Table of Contents

Other manuals for HP 5920 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP 5920 Series and is the answer not in the manual?

HP 5920 Series Specifications

General IconGeneral
BrandHP
Model5920 Series
CategorySwitch
LanguageEnglish

Related product manuals