Typical
Configu
ration
Static
power
consump
tion
Maximu
m power
consump
tion
Typical
power
consum
ption
Board configuration
GPON
(H801SC
UH
+H803G
PFD)
786.84 1253.55 1020.195 H801SCUH*2+H801X2CS*2+H801CI
TD+H801PRTE*2+H801FCBH
+H806GPBD/H802GPFD*14
NOTE
The power consumption of the subrack is tested in the following conditions:
l Working voltage: -53.5 V DC
l Ambient temperature of 25 °C
l Static power consumption: All ports do not carry any loads. Specifically, users under POTS ports
hang up phones, xDSL ports are deactivated, and optical modules are not installed on optical ports
l Maximum power consumption: All ports fully carry loads. However, only 25% users under POTS
ports concurrently pick up phones and the feeding current is 20 mA.
l Typical power consumption: half of the total value of static power consumption and maximum
power consumption.
l The preceding table lists power consumption under typical configuration. For power consumption
under other configurations, use Access Network Hardware Configuration Tool.
l In the case of Access device, power consumption is generally transformed into heat consumption.
Hence, heat consumption (BTU/h) and power consumption (W) can be converted to each other in
the formula: 1 BTU/h = 0.2931 W.
2.3.3 Configuration
The IEC service subrack provides 14 slots for service boards, two slots for control boards,
two slots for power boards, one for universal interface board and tow for upstream interface
boards. This topic lists the types of boards supported by the IEC service subrack and the slot
restriction.
Configuration
H801MABH and H802MABH are the backplane supported by the IEC service subrack.
H801MABH does not support the Vectoring feature, H802MABH supports the Vectoring
feature.
SmartAX MA5600T/MA5603T/MA5608T Multi-service
Access Module
Hardware Description
2 Subrack and Chassis
Issue 24 (2018-07-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
91