H2: Auxiliary function outputs to PLC
8.18 Data lists
Basic Functions
Function Manual, 09/2011, 6FC5397-0BP40-2BA0
473
8.18 Data lists
8.18.1 Machine data
8.18.1.1 NC-specific machine data
8.18.1.2 Channelspecific machine data
Number Identifier: $MN_ Description
10713 M_NO_FCT_STOPRE M function with preprocessing stop
10714 M_NO_FCT_EOP M function for spindle active after NC RESET
10715 M_NO_FCT_CYCLE M function to be replaced by subroutine
11100 AUXFU_MAXNUM_GROUP_ASSIGN Maximum number of user-defined auxiliary functions
per channel
11110 AUXFU_GROUP_SPEC Group-specific output behavior
11450 SEARCH_RUN_MODE Behavior after a block search
Number Identifier: $MC_ Description
20110 RESET_MODE_MASK Definition of control initial setting after part program
start.
20112 START_MODE_MASK Definition of control initial setting after powerup and
on RESET or at end of part program
20270 CUTTING_EDGE_DEFAULT Basic setting of tool cutting edge without programming
20800 SPF_END_TO_VDI Subroutine end / Stop at PLC
22000 AUXFU_ASSIGN_GROUP Group assignment of user-defined auxiliary functions
22010 AUXFU_ASSIGN_TYPE Type of user-defined auxiliary functions
22020 AUXFU_ASSIGN_EXTENSION Address extension for user-defined auxiliary functions
22030 AUXFU_ASSIGN_VALUE Value of user-defined auxiliary functions
22035 AUXFU_ASSIGN_SPEC Output behavior of user-defined auxiliary functions
22040 AUXFU_PREDEF_GROUP Group assignment of predefined auxiliary functions
22050 AUXFU_PREDEF_TYPE Type of predefined auxiliary functions
22060 AUXFU_PREDEF_EXTENSION Address extension for predefined auxiliary functions
22070 AUXFU_PREDEF_VALUE Value of predefined auxiliary functions
22080 AUXFU_PREDEF_SPEC Output behavior of predefined auxiliary functions
22100 AUXFU_QUICK_BLOCKCHANGE Block change delay with quick auxiliary functions
22110 AUXFU_H_TYPE_INT Type of H auxiliary functions
22200 AUXFU_M_SYNC_TYPE M functions output time
22210 AUXFU_S_SYNC_TYPE S functions output time
22220 AUXFU_T_SYNC_TYPE T functions output time