K1: Mode group, channel, program operation, reset response
9.12 Single block
Basic Functions
Function Manual, 09/2011, 6FC5397-0BP40-2BA0
611
9.12.3 Single block stop: inhibit according to situation
Suppress stopping in single cases
Depending on
MD10702 $MN_IGNORE_SINGLEBLOCK_MASK (Prevent single block stop)
setting bits 0 to 12 = 1 can suppress stopping at the end of the block during the following machining processes.
Program execution must not stop after single blocks in the case of the following even if block-by-block processing
is selected:
1. An internal Asub
2. during a user ASUP
3. Subroutines with the attribute DISPLOF
4. Intermediate blocks
5. Block search group blocks
6. Init blocks
7. Blocks, which cannot be reorganized
8. Blocks, which are not repositionable
9. A repositioning block, which contains no traversing information
10.A prerun/main run/synchronization block, due to REORG
11.at a Tool selection block.
12.At a GET block
13.During a single block type 2
Sequence
If an ASUB is activated during the single block, for example, execution of the ASUB is completed. The
deceleration movement does not take place until after the end of the ASUB or the first IPO block in which single-
block suppression is not activated. If the velocity is too large for the deceleration to be performed in this block
(with continuouspath mode G64 active), G64), further block changes are allowed.
For decoding single block, MD10702 is only effective with "internal ASUB", "user ASUB" and "subroutines with
the attribute DISPLOF". In these cases, it is already clear at the time of interpretation that the block belongs to
one of the above categories. In these cases, further blocks can be generated.
SBLON in ASUB
The single block stop of an internal ASUP or user ASUP that is suppressed with MD10702
$MN_IGNORE_SINGLEBLOCK_MASK can be reactivated in ASUP by programming SBLON.
This functionality can be suppressed again with MD20117 $MC_IGNORE_SINGLEBLOCK_ASUB. The SBLON
command then becomes ineffective.

Table of Contents

Other manuals for Siemens SINUMERIK 828D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 828D and is the answer not in the manual?

Siemens SINUMERIK 828D Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 828D
CategoryControl Systems
LanguageEnglish

Related product manuals