K2: Axis Types, Coordinate Systems, Frames
10.5 Frames
Basic Functions
794 Function Manual, 09/2011, 6FC5397-0BP40-2BA0
10.5.10 Data backup
Data block _N_CHANx_UFR is used to archive the system frames.
Machine data
MD28082 $MC_MM_SYSTEM_FRAME_MASK
should not have changed between saving and reintroducing the saved system frames. If it has changed then it is
possible that saved system frames could no longer be loaded.
In this case, the loading process triggers an alarm.
Data backup always takes place in accordance with the currently valid geometry axis assignment, not in
accordance with the axis configurations set in the machine data.
The machine data
$MC_MM_SYSTEM_DATAFRAME_MASK
can be used to configure data management frames for the system frames.
If you do not want a data management frame for a system frame, the frame does not have to be saved. With
G500, G54 to G599, the active frame is retained.
A separate data block _N_NC_UFR is used to archive global frames.
The block requested by the HMI is created if the machine data
MD18601 $MN_MM_NUM_GLOBAL_USER_FRAMES
or
MD18602 $MN_MM_NUM_GLOBAL_BASE_FRAMES
has a value greater than zero.
Channel-specific frames are saved in data block _N_CHANx_UFR.
In certain circumstances, alarms could be triggered when reintroducing saved data, if the frame affiliates, be they
NCU global or channel-specific, have been changed using machine data.
Data backup always takes place in accordance with the axis configuration set in the machine data, not in
accordance with the currently valid geometry axis assignment.
10.5.11 Positions in the coordinate system
The setpoint positions in the coordinate system can be read via the following system variables. The actual values
can be displayed in the WCS, SZS, BZS or MCS via the PLC. There is a softkey for actual-value display in MCS/
WCS. Machine manufacturers can define on the PLC side, which coordinate system corresponds to the
workpiece coordinate system on their machines. The HMI requests the appropriate actual values from the NCK.
$AA_IM[axis]
The setpoints in the machine coordinate system can be read for each axis using the variables $AA_IM[axis].
$AA_IEN[axis]
The setpoints in the settable zero system (SZS) can be read for each axis using the variables $AA_IEN[axis].
$AA_IBN[axis]
The setpoints in the basic zero system (BZS) can be read using the variable $AA_IBN[axis].
$AA_IW[axis]
The setpoints in the workpiece coordinate system (WCS) can be read using the variable $AA_IW[axis].

Table of Contents

Other manuals for Siemens SINUMERIK 828D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 828D and is the answer not in the manual?

Siemens SINUMERIK 828D Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 828D
CategoryControl Systems
LanguageEnglish

Related product manuals