:HARDcopy Commands 17
Agilent InfiniiVision 3000 X-Series Oscilloscopes Programmer's Guide 361
:HARDcopy:FACTors
(see page 1138)
Command Syntax
:HARDcopy:FACTors <factors>
<factors> ::= {{OFF | 0} | {ON | 1}}
The HARDcopy:FACTors command controls whether the scale factors are
output on the hardcopy dump.
Query Syntax
:HARDcopy:FACTors?
The :HARDcopy:FACTors? query returns a flag indicating whether
oscilloscope instrument settings are output on the hardcopy.
Return Format
<factors><NL>
<factors> ::= {0 | 1}
See Also • "Introduction to :HARDcopy Commands" on page 358
• ":HARDcopy:STARt" on page 373
• ":HARDcopy:FFEed" on page 362
• ":HARDcopy:INKSaver" on page 363
• ":HARDcopy:LAYout" on page 364
• ":HARDcopy:PALette" on page 371

Table of Contents