:POWer Commands 24
Agilent InfiniiVision 3000 X-Series Oscilloscopes Programmer's Guide 579
:POWer:SIGNals:VSTeady:ONOFf:ON
(see page 1138)
Command Syntax
:POWer:SIGNals:VSTeady:ONOFf:ON <value>[suffix]
<value> ::= Expected steady state output Voltage value in NR3 format
[suffix] ::= {V | mV}
The :POWer:SIGNals:VSTeady:ONOFf:ON command specifies the expected
steady state output DC voltage of the power supply for turn on analysis.
Query Syntax
:POWer:SIGNals:VSTeady:ONOFf:ON?
The :POWer:SIGNals:VSTeady:ONOFf:ON query returns the expected steady
state voltage setting.
Return Format
<value><NL>
<value> ::= Expected steady state output Voltage value in NR3 format
See Also • ":POWer:ONOFf:APPLy" on page 553
• ":POWer:SIGNals:AUTosetup" on page 564
• ":POWer:SIGNals:DURation:ONOFf:ON" on page 570
• ":POWer:SIGNals:IEXPected" on page 573
• ":POWer:SIGNals:OVERshoot" on page 574
• ":POWer:SIGNals:VMAXimum:ONOFf:ON" on page 577
• ":POWer:SIGNals:SOURce:CURRent<i>" on page 581
• ":POWer:SIGNals:SOURce:VOLTage<i>" on page 582