:SBUS<n> Commands 27
Agilent InfiniiVision 3000 X-Series Oscilloscopes Programmer's Guide 647
:SBUS<n>:A429:TRIGger:PATTern:SDI
(see page 1138)
Command Syntax
:SBUS<n>:A429:TRIGger:PATTern:SDI <string>
<string> ::= "nn" where n ::= {0 | 1 | X}, length always 2 bits
The :SBUS<n>:A429:TRIGger:PATTern:SDI command defines the ARINC 429
two- bit SDI pattern resource according to the string parameter. This
pattern controls the SDI pattern searched for in each ARINC 429 word.
The specified SDI is only used if the :SBUS<n>:A429:FORMat includes the
SDI field.
Query Syntax
:SBUS<n>:A429:TRIGger:PATTern:SDI?
The :SBUS<n>:A429:TRIGger:PATTern:SDI? query returns the current
settings of the specified ARINC 429 two- bit SDI pattern resource in the
binary string format.
Return Format
<string><NL> in nondecimal format
Errors • "- 241, Hardware missing" on page 1099
See Also • "Introduction to :TRIGger Commands" on page 877
• ":SBUS<n>:A429:FORMat" on page 641
• ":SBUS<n>:A429:TRIGger:TYPE" on page 650
• ":SBUS<n>:A429:TRIGger:PATTern:DATA" on page 646
• ":SBUS<n>:A429:TRIGger:PATTern:SSM" on page 648