:RECall Commands 25
Agilent InfiniiVision 3000 X-Series Oscilloscopes Programmer's Guide 601
:RECall:MASK[:STARt]
(see page 1138)
Command Syntax
:RECall:MASK[:STARt] [<file_spec>]
<file_spec> ::= {<internal_loc> | <file_name>}
<internal_loc> ::= 0-3; an integer in NR1 format
<file_name> ::= quoted ASCII string
The :RECall:MASK[:STARt] command recalls a mask.
See Also • "Introduction to :RECall Commands" on page 598
• ":RECall:FILename" on page 600
• ":SAVE:MASK[:STARt]" on page 616
• ":MTESt:DATA" on page 504
NOTE
If a file extension is provided as part of a specified <file_name>, it must be ".msk".