930 Agilent InfiniiVision 3000 X-Series Oscilloscopes Programmer's Guide
31 :TRIGger Commands
:TRIGger:RUNT:SOURce
(see page 1138)
Command Syntax
:TRIGger:RUNT:SOURce <source>
<source> ::= CHANnel<n>
<n> ::= 1 to (# analog channels) in NR1 format
The :TRIGger:RUNT:SOURce command selects the channel used to produce
the trigger.
Query Syntax
:TRIGger:RUNT:SOURce?
The :TRIGger:RUNT:SOURce? query returns the current runt trigger source.
Return Format
<source><NL>
<source> ::= CHAN<n>
See Also • "Introduction to :TRIGger Commands" on page 877
• ":TRIGger:RUNT:POLarity" on page 928