C Commands
collect timestamp sys-uptime
85
Cisco Nexus 7000 Series NX-OS System Management Command Reference
OL-25806-03
collect timestamp sys-uptime
To configure the TIMESTAMP SYS-UPTIME field as a nonkey field and collect the values in them for
a Flexible NetFlow flow record, use the collect
timestamp sys-uptime command. To disable the use of
the TIMESTAMP SYS-UPTIME field as a nonkey for a Flexible NetFlow flow record, use the no form
of this command.
collect timestamp sys-uptime {first | last}
no collect timestamp sys-uptime {first | last}
Syntax Description
Defaults This command is not enabled by default.
Command Modes Flow record configuration
Supported User Roles network-admin
vdc-admin
Command History
Usage Guidelines The Flexible NetFlow commands that start with collect are used to configure nonkey fields for the flow
monitor record and to enable capturing the values in the fields for the flow created with the record. The
values in nonkey fields are added to flows to provide additional information about the traffic in the flows.
A change in the value of a nonkey field does not create a new flow. In most cases, the values for nonkey
fields are taken from only the first packet in the flow.
This command does not require a license.
Examples This example shows how to configure timestamps based on the sys-uptime for the time that the first
packet was seen from the flows as a nonkey field and collects the sys-uptime for the time that the first
packet was seen from the flows:
switch(config)# flow record FLOW-RECORD-1
switch(config-flow-record)# collect timestamp sys-uptime first
first Configures the sys-uptime for the time that the first packet was seen from the
flows as a nonkey field and collects time stamps based on the sys-uptime for
the time that the first packet was seen from the flows.
last Configures the sys-uptime for the time that the last packet was seen from the
flows as a nonkey field and collects time stamps based on the sys-uptime for
the time that the most recent packet was seen from the flows.
Release Modification
4.0(1) This command was introduced.

Table of Contents

Other manuals for Cisco Nexus 7000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco Nexus 7000 Series and is the answer not in the manual?

Cisco Nexus 7000 Series Specifications

General IconGeneral
ChassisModular
Operating SystemCisco NX-OS
LatencySub-microsecond
IPv6 SupportYes
RedundancyPower supplies, fans, supervisors, fabric modules
Power SupplyAC or DC
Layer SupportL2, L3
Network ManagementCLI, SNMP
VirtualizationVRF, vPC
Ports10 Gigabit Ethernet, 40 Gigabit Ethernet, 100 Gigabit Ethernet, Fibre Channel, Fibre Channel over Ethernet (FCoE)
Supported ModulesVarious (1G, 10G, 40G, 100G)
FeaturesFCoE, OTV, LISP
MPLS SupportYes
Quality of Service (QoS)Yes
Security FeaturesACLs, Cisco TrustSec, Control Plane Policing (CoPP)
DimensionsVaries by model
WeightVaries by model
Operating Temperature0 to 40°C (32 to 104°F)
Storage Temperature-40°F to 158°F (-40°C to 70°C)
Humidity5 to 95% noncondensing
MTBFVaries by model
Number of SlotsVaries by model (9-slot, 10-slot, 18-slot)