rmon alarm
To configure a 32-bit remote monitoring RMON alarm, use the rmon alarm command. To delete RMON
alarms, use the no form of this command.
rmon alarm alarm number mib-object sample-interval {absolute | delta} rising-threshold value
[rising-event] falling-threshold value [falling-event] [owner alarm-owner]
no rmon alarm alarm-number
Syntax Description
Defaults None
Command Modes Global configuration mode
Supported User Roles network-admin
vdc-admin
Command History
Usage Guidelines This command does not require a license.
alarm number RMON alarm number. The range is from 1 to 65535.
mib-object MIB object to monitor. The maximum length is 80 characters.
sample-interval Sample interval in seconds. The range is from 1 to 2147483647.
absolute Specifies to test each sample directly.
delta Specifies to test the difference (delta) between the current and previous sample.
rising-threshold
value
Specifies the rising threshold value. The range is from 2147483648 to 2147483647.
rising-event (Optional) Event to trigger on a rising threshold crossing. The range is from 1 to
65535. If no event is specified, event 0 is used.
falling-threshold
value
Specifies the falling threshold value. The range is from 2147483648 to
2147483647.
falling-event (Optional) Event to trigger on a falling threshold crossing. The range is from 1 to
65535. If no event is specified, event 0 is used.
owner alarm
owner
(Optional) Specifies an owner for the alarm. The maximum size is 80 characters.
Release Modification
4.0(1) This command was introduced.