-switch Displays the settings of rotary switches on the device, e.g. the NC and PLC
switches of an NCU or the DIPFIX of an HT 8.
-all Equivalent to all the above switches.
Note
The data and information read out here are automatically written to the EUNA file (End User
Notification Administration), and saved on the associated device.
2.5.19 Start, Stop
Description
Syntax: sc start all|system|SUBSYSTEM...
sc stop all|system|SUBSYSTEM...
Alternative names: ---
Authorization level: service
These two actions start or stop individual or all subsystems. Since these actions have a direct
influence on the runtime behavior, they are available only directly on the control, but not in the
service system (exception: "sc stop system"). The subsystems of the associated control do
not run here, and can therefore not be controlled.
Note
Only "all" and "system" function, but not arbitrary subsystems. Both of these actions have been
implemented only to a limited extent.
Subsystem names
"hmi", "nck" or any other names can be used for the subsystems. Multiple subsystems can
also be specified successively; they are then started and stopped in this order.
"all" and "system" are special values for the subsystem:
● "all" starts or stops all available subsystems.
● "sc stop system" also stops all subsystems and the basic system with the control.
● "sc start system" is identical to "sc start all" and exists mainly for reasons of symmetry.
Configuring the system
2.5 Description of the actions
NCU operating system
60 Commissioning Manual, 12/2017, 6FC5397-1DP40-6BA1