Select the required storage location, press the "Search" softkey and enter
the required search term. Then press the "OK" softkey if you wish to
search for a certain directory, subdirectory or start-up archive.
5. Press the "OK" softkey.
The "Read-in Start-up Archive" window opens.
You obtain an overview with path details, version information, name of
the archive, etc., as well as a list of the archived components.
Remove the tick of a checkbox to exclude a component from the read-in
process.
6. Press the "OK" softkey to download the selected archive file.
The "Read-in Archive" window opens and a progress message box ap‐
pears for the read-in process.
7. Press the "Overwrite all" softkey if you wish to overwrite the existing files.
- OR -
Press the "No overwriting" softkey if you wish to keep existing files.
- OR -
Press the "Skip" softkey if you only wish to overwrite certain files.
You will then obtain a "Read error log for archive" in which the skipped or
overwritten files are listed.
8. Press the "Cancel" softkey to cancel the read-in process.
16.4 Backing up the hardware configuration
The hardware is configured via the system data blocks (SDB) and only these are stored in the
archive.
Procedure
1. Select the "Start-up" operating area.
Press the menu forward key.
2. Press the "Start-up archive" softkey.
The "Start-up" window opens.
Data backup
16.4 Backing up the hardware configuration
SINUMERIK Operate (IM9)
360 Commissioning Manual, 12/2017, 6FC5397-1DP40-6BA1