4.17.2 Factory setting of the Windows Firewall on the Siemens PC system
The Windows Firewall settings on your Siemens PC system are appropriately configured by
the PCU-Basesoftware for the use of SINUMERIK software and systems. For security reasons,
the Windows Firewall is activated in the company network and expanded by additional rules.
The Windows Firewall is deactivated in the system network. The descriptions in this chapter
therefore largely relate to the adaptation of the firewall settings for the company network.
Table 4-6 Factory settings for network adapter and Windows Firewall
System network Company network
Interface X2 X1
Network name for PCU 50.5 Local Area Connection Local Area Connection 2
Network profile Public Public
Status Windows Firewall
See: General information on the settings
recommended for Windows (Page 70)
Deactivated Activated
File and printer release
See: Activation/deactivation of the file
and printer release (Page 76)
Activated and permit‐
ted
Deactivated and blocked by firewall
SNMP communication
See: Enabling SNMP communication
(Page 71)
Permitted Blocked
Remote access (via port 5900)
See: Activate the remote access to the
PC system (Page 73)
Permitted Blocked
Outgoing ICMP Ping requests from the
PC system
See: Activation of the ping execution
(ICMP) (Page 88)
Permitted Permitted
Incoming ICMP Ping requests on the PC
system
See: Activation of the ping execution
(ICMP) (Page 88)
Permitted Blocked
Note
Automatic network release of USB data storage media results in activation of the file and printer
release
The automatic network release of USB data storage media is activated in the default setting
of the NCU-Basesoftware. The file and printer release is then activated by Windows when a
USB data storage medium is connected.
See: Configuring network access on the USB data storage medium (Page 34)
See also
Patch management and security updates (Page 96)
Saving and restoring firewall settings (Page 90)
Configuration of the system
4.17 Adapting the firewall settings
PCU Base Software (IM10)
68 Commissioning Manual, 12/2017, 6FC5397-1DP40-6BA1

Table of Contents

Other manuals for Siemens SINUMERIK 840DE SL

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 840DE SL and is the answer not in the manual?

Siemens SINUMERIK 840DE SL Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 840DE SL
CategoryControl Systems
LanguageEnglish

Related product manuals