Appendix
A-30
Appendix
Setting data list
25.0
0.0
M
M
manu
25.0
0.0
M
bnk.0
25.0
0.0
M
25.0
0.0
M
rsp
0.0
M
sp-m
0.0
M
o
0.0
M
0.0
M
r-s
run
M
a-m
auto
0.0
bnk.0
c-o
0.0
M
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
bank
0
CH
at
off
CH
cmwt
off
spmd
lsp
CH
c-sc
1.00
CH
c-db
0.00
CH
of-r
50.0
CH
hys
0.10
CH
M
chys
0.10
CH
cp
20.0
CH
c-cp
20.0
CH
db
2.0
CH
oc-h
0.8
CH
sprh
CH
sprl
CH
0.0
CH
CH
0.0
orl
CH
corl
0.0
CH
isi.1
-200.0
CH
iss.1
0.00
CH
isi. 2
1300.0
CH
iss. 2
0.00
CH
dogn
0.65
CH
dotc
1.00
CH
do-b
CH
0.000
dojw
0.00
CH
spru
m
CH
M
0.0
0.0
0.0
+
lagp.1
ma p.1
ma p.2
sqrp.1
sqrp.2
ap.1
0.000
0.000
0.0
0.0
1.000
1
1
M
M
M
M
M
M
lagp.2
M
lagp.3
0.0
0.0
M
lagp.4
M
ma p.3
ma p.4
1
1
M
M
sqrp.3
sqrp.4
0.000
0.000
M
M
oapt
0
icpt
0
wtpt
off
M
M
M
l.prt
M
pfpt
off
l.ad2
l.adj
M
L
LL
+
M
L
For the input initial setting level, see page A-32
L
key 3 seconds or more
Control stops
Power on
OAPT:
Operation Adjustment Protect
0-4
ICPT:
Initial setting protect
0-2
WTPT:
Setting change protect
OFF(0) / ON(1)
PFPT:
PF key protect
OFF(0) / ON(1)
Protect Levels
Operation Level
Adjustment
Level
Adjustment
2 Level
Power on
At least 1 second
less than 1 second less than 1 second
At least 3 seconds
PV / Manual MV
(Position proportional
control type:
PV / Valve opening)
1
PV / SP (Display 1)
PV / SP / bank No.
2
PV / SP (Display 2)
Present / SP / MV
PV / SP (Display 3)
Present / SP / bank No.
RSP: Remote SP monitor
SP-M: Ramp SP monitor
O: MV monitor (heating)
C-O: MV monitor (cooling)
V-M: Valve opening monitor
R-S: RUN / STOP
A-M: AUTO / MANU
1: In manual mode
2: One of the following is displayed depending
on the "Display screen selection" setting:
1. Display 1 / Display 2
2. Display 2 / Display 3
3. Display 1 only
4. Display 2 only
BANK: Bank No.
0-7
CMWT: Write via
communication
OFF / ON
AT: AT execute/cancel
OFF / 0-8
SPMD: SP mode
LSP / RSP
C-SC:
Cooling coefficient
0.01-99.99
OF-R:
Manual reset value
0.0-100.0
C-DB: Dead band
-199.99-999.99
HYS:
Hysteresis (heating)
0.01-99.99
CHYS:
Hysteresis (cooling)
0.01-99.99
CP:
Control period (heating)
0.2-99.0
C-CP:
Control period (cooling)
0.2-99.0
DB:Position proportional
dead band
0.1-10.0
OC-H:
Open / close hysteresis
0.1-20.0
SPRU: SP ramp time unit
EU / sec: S, EU / min: M,
EU / hour: H
SPRH: SP ramp rise value
0-99999
(0: Disable SP ramp function)
SPRL: SP ramp fall value
0-99999
(0: Disable SP ramp function)
MV-S: MV at stop
-5.0-105.0
(standard type) 1
MV-E: MV at PV error
-5.0-105.0
(standard type) 1
ORL: MV change rate limit
(heating)
0.0-100.0
CORL: MV change rate limit
(cooling)
0.00-100.0
ISI.1: Input value 1 for
input correction
-19999-99999
ISS.1: Input correction 1
-199.99-999.99
ISI.2: Input value 2 for
input correction
-19999-99999
ISS.2: Input correction 2
-199.99-999.99
DOGN: Disturbance gain
-1.00-1.00
DOTC: Disturbance
time constant
0.01-99.99
DO-B: Disturbance
rectification band
0.000-9.999
DOJW: Disturbance
judgement width
-99.99-99.99
1 Position proportional type: Closed / Hold / Open (-1/0/1)
LAGP.1: First order lag
operation 1: Time constant
0.0-999.9
LAGP.2: First order lag
operation 2: Time constant
0.0-999.9
LAGP.3: First order lag
operation 3: Time constant
0.0-999.9
MAVP.1: Move average 1
Move average count
1 / 2 / 4 / 8 / 16 / 32
LAGP.4: First order lag
operation 4: Time constant
0.0-999.9
MAVP.2: Move average 2
Move average count
1 / 2 / 4 / 8 / 16 / 32
MAVP.3: Move average 3
Move average count
1 / 2 / 4 / 8 / 16 / 32
MAVP.4: Move average 4
Move average count
1 / 2 / 4 / 8 / 16 / 32
SQRP.1:
Extraction of square root 1
Low-cut point
0.000-9.999
SQRP.2:
Extraction of square root 2
Low-cut point
0.000-9.999
SQRP.3:
Extraction of square root 3
Low-cut point
0.000-9.999
SQRP.4:
Extraction of square root 4
Low-cut point
0.000-9.999
AP.1: Analog parameter
Control rate
-1.999-9.999