2-496
Catalyst 3750-X and 3560-X Switch Command Reference
OL-29704-01
Chapter 2 Catalyst 3750-X and 3560-X Switch Cisco IOS Commands
power xps (global configuration)
power xps (global configuration)
To configure a name for the Cisco eXpandable Power System 2200 (XPS 2200) that is connected to a
Catalyst 3750-X or 3650-X switch, or to configure the XPS port used for the connection, use the power
xps command in global configuration mode. To remove the name, use the no form of the command.
power xps switch-number {name {name | serialnumber} | port port-number {name | hostname |
serialnumber}}
no power xps switch-number {name {name | serialnumber} | port port-number {name | hostname
| serialnumber}}
Syntax Description
The name of the XPS 2200 and XPS ports are not configured.
Command Modes Global configuration
Command History
Usage Guidelines The XPS name is a 16-character maximum character string. In a standalone switch, the name applies to
the connected XPS. In a switch stack, the name applies to the XPS connected to the specified switch.
Use the no power xps switch-number name command to remove the system name. Use the no power
xps switch-number port command to remove the port name.
switch-number Specifies the stack member to which the XPS 2200 is connected. The
range is 1 to 9, depending on the switch member numbers in the stack.
This variable appears only on Catalyst 3750-X switches.
name {name |
serialnumber}
Configures a name for the XPS:
• name—Specifies the name such as port1 or port 1. Using quotation
marks before and after the name is optional, but you must use
quotation marks if you want to include spaces in the port name. The
name can have up to 16 characters.
• serialnumber—Configures the switch to use the XPS serial number
as the name.
Note The switch name is saved at the switch, not at the XPS.
port port-number {name |
hostname | serialnumber}
Configures a name for an XPS port connected to a switch.
• port-number—The port number range is from 1 to 9.
• hostname—Use the hostname of the switch connected to the port as
the port name.
• serialnumber—Configures the switch to use the switch serial
number as the port name.
Release Modification
12.2(55)SE1 This command was introduced.

Table of Contents

Other manuals for Cisco Catalyst 3750-X

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco Catalyst 3750-X and is the answer not in the manual?

Cisco Catalyst 3750-X Specifications

General IconGeneral
BrandCisco
ModelCatalyst 3750-X
CategorySwitch
LanguageEnglish

Related product manuals