2-625
Catalyst 3750-X and 3560-X Switch Command Reference
OL-29704-01
Chapter 2 Catalyst 3750-X and 3560-X Switch Cisco IOS Commands
show env
show env
Use the show env user EXEC command to display fan, temperature, redundant power system (RPS)
availability, and power information for the switch or the switch stack.
show env {all | fan | power [all | switch [switch-number]] | rps | stack [switch-number] |
temperature [status] | xps}
Syntax Description
Command Modes User EXEC
Command History
all Display the fan and temperature environmental status and the status of the internal
power supplies and the RPS.
fan Display the switch fan status.
power Display the switch internal power status.
power all (Optional) Display the status of all the internal power supplies in a standalone
switch when the command is entered on the switch or in all the stack members
when the command is entered on the stack master.
power switch
[switch-number]
(Optional) Display the status of the internal power supplies for each switch in the
stack or for the specified switch. The range is 1 to 9, depending on the switch
member numbers in the stack.
These keywords are available only on Catalyst 3750-E switches.
rps Display whether a redundant power system is connected to a Catalyst 3750-E or
Catalyst 3750 switch in the stack as follows:
• Catalyst 3750-E—Cisco Redundant Power System 2300, also referred to as
the RPS 2300.
• Catalyst 3750 switch—the RPS 2300 or Cisco RPS 675 Redundant Power
System, also referred to as the RPS 675.
Note Catalyst 3750-X and 3560-X switches do not connect to redundant power
systems.
stack
[switch-number]
Display all environmental status for each switch in the stack or for the specified
switch. The range is 1 to 9, depending on the switch member numbers in the stack.
This keyword is available only on stacking-capable switches.
temperature Display the switch temperature status.
temperature
status
(Optional) Display the switch internal temperature (not the external temperature)
and the threshold values.
xps (Optional) Display information for the Cisco eXpandable Power System (XPS)
2200. See the show env xps command.
Release Modification
12.2(53)SE2 This command was introduced.